The modified rules for punching were applied for design of slabs and the graphs of minimal depths were calculated for this structural member for different loads, reinforcement and concrete classes. The punching of slabs has a character of fragile failure and therefore shear resistance of slabs with shear reinforcement (studs) located after appropriate detailing has to be restricted to 1,9 multiple of shear concrete resistance in appropriate control circuit.